Overcrank, Code 1100

Description: Occurs when the generator attempts to start multiple times without success.

Action: Check if the gas is on. If the issue persists, contact an authorized service dealer.

Overspeed, Code 1200/1205

Description: Indicates the generator is running at higher RPM than normal.

Action: Possible defective ignition coils. Contact an authorized service dealer.

Low Oil Pressure, Code 1300

Description: Appears when oil pressure is low.

Action: Check and adjust the oil level as per the owner’s manual. If the issue continues, a service call is needed.

How to Shut Down Generator During Powering House

Description: Steps to safely shut down the generator during a utility outage.

Action: Follow the detailed steps provided, including setting utility and generator disconnects to OFF and removing the 7.5A fuse from the controller.

RPM Sense Loss, Code 1501/1505/1511/1515

Description: Indicates an issue with detecting the engine’s RPMs.

Action: Clear the alarm, remove some loads, and try restarting. If it doesn’t start, place a service call.

Underspeed, Code 1600

Description: Triggered when the correct RPM is not detected by the controller.

Action: Contact an authorized service dealer.

Undervoltage, Code 1900

Description: Indicates a sudden drop in voltage.

Action: A service call is required.

Overload, Code 2100

Description: Appears when an overload condition is detected.

Action: Remove the load. If the problem persists, a service call is necessary.

Low Battery

Description: Suggests an issue with the battery voltage.

Action: Check the battery voltage and the charge circuit. Recharge if below 12.5 VDC.